| Description
FREE SHIPPING & CALL FOR BETTER PRICING!
GF200 & GF300 are the "class A" approved pharmacy balances !
The GF Series incorporates our unique SHS technology and defies comparison with all others. Our revolutionary and patented Super Hybrid Sensor (SHS) technology improves response speed and inimizes maintenance costs. Its unique design provides the fastest response speed in its class-an amazing one-second. SHS combines the best of magnetic force restoration and single point parallelogram load sensing technologies. This balance (especially the GF200 & GF300) are specifically designed as class A balances for pharmacies across the United States.
|
Features |
|
Legal for Trade (as noted below)
Fast, new Super Hybrid Sensor (SHS) gives you the ultimate in response speed - Just ONE Second!
Resolution Range among models: 1/60,000 to 1/600,000
Large, bright Vacuum Fluorescent Display - see the display even in the dark
Percentage, Counting Functions & Comparator functions
ACAI Counting Function for highly accurate counting
GLP/GMP/ISO Compliance 
Glass Breeze Break (Option) |

FAQ's Is this a "class A" pharmacy balance? Yes, the GF200 and GF300 are class A pharmacy balances. This balance can do compounding and pill counting (pill counting: GF200P & GF300P models - add $100 for these models). The pill counting is a brand new feature that has been NTEP approved (legal for trade). Please call in your order at 800-620-7811 if you'd like the pill counting version.
The GF Series in Counting Applications:
Richard, Arthur and David Williams, owners of The D. R. Templeman Company, knew that they had a problem with accurate spring counts.  This was especially true for the smaller springs with unit weights as low as 0.005 pounds per thousand (2 grams per thousand).  The problem was compounded by the fact that the unit weight would vary each time the physical dimensions were adjusted to meet critical load specifications.  The process of counting out a sample of at least 100 pieces, weighing them on a mechanical balance beam scale, calculating a unit weight and using the unit weight to determine piece counts was both time consuming and error prone.  To compensate for these deficiencies, Templeman was routinely giving away an extra 2% of springs in every box in order to avoid complaints of short shipments.
In their search for an accurate counting system, they discovered electronic balances that would give them an accurate unit weight, but would not transfer that unit weight to a larger scale for bulk counts.  They discovered larger capacity scales that could count in bulk, but did not have a high enough resolution to accurately determine the unit weight.  Then they contacted Bob Dumas at Commercial Scale and Balance Company of Agawam, MA.  Bob listened to their concerns and provided a unique solution to their problem.
Using the flexibility built into an A&D balance (200g x 0.001g), Commercial Scale was able to couple the balance to a programmable indicator, which was also coupled to 5 pound and 50 pound scales.  Commercial Scale was then able to write a program for accurately determining unit weights using input from the A&D balance and then use that unit weight to determine piece counts on the balance, the 5 pound scale or the 50 pound scale.  Also built into the program is the ability to store Customer and Part Number data and to print customized barcode labels right at the scale location.  This system gives Templeman the range needed to count their smallest and their largest springs.
Richard Williams says that the unique solution developed by Commercial Scales has greatly increased the accurate of their piece counts and the efficiency of their packing operation.  They no longer feel the need to add an extra 2% in each box and have had fewer complaints about short shipments.  The accuracy of the new counting system has given them the confidence to challenge the complaints they have received and to prevail.

|
Specifications
| Specifications |
GF-200* |
GF-300* |
GF-400 |
GF-600 |
GF-1200* |
| Weighing capacity |
210g |
310g |
410g |
610g |
1210g |
| Minimum weighing value |
0.001g |
0.01g |
| Repeatability (Standard Deviation) |
0.001g |
0.01g |
| Decimal ounce (oz) |
7.40755x0.00005 |
10.93495x0.00005 |
14.46230x0.00005 |
21.51710x0.00005 |
42.6815x0.0005 |
| Troy ounce (ozt) |
6.75165x0.00005 |
9.96675x0.00005 |
13.18180x0.00005 |
19.61195x0.00005 |
38.9025x0.0005 |
| Pennyweight (dwt) |
135.033x0.001 |
199.335x0.001 |
263.636x0.001 |
392.239x0.001 |
778.05x0.01 |
| Carat (ct) |
1050.000x0.005 |
1550.000x0.005 |
2050.000x0.005 |
3050.000x0.005 |
6050.00x0.05 |
| Momme (mom) |
56.0000x0.0005 |
82.6665x0.0005 |
109.3335x0.0005 |
162.6665x0.0005 |
322.665x0.005 |
| Grain unit (GN) |
3240.80x0.02 |
4784.04x0.02 |
6327.26x0.02 |
9413.74x0.02 |
18673.2x0.2 |
| Pound (lb) |
0.462970x0.000005 |
0.683435x0.000005 |
0.903895x0.000005 |
1.344820x0.000005 |
2.66760x0.00005 |
| Pound/Ounce (lb/oz) |
0Lb 7.41oz x0.01oz |
0Lb 10.93oz x0.01oz |
0Lb 14.46oz x0.01oz |
1Lb 5.52oz x0.01oz |
2Lb 10.68oz x0.01oz |
| Linearity |
0.002g |
0.003g |
0.02g |
| Stabilization time (typical at FAST) |
Approx. 1 second |
| Sensitivity drift (10C to 30C/50F-80F) |
2ppm/°C (When automatic self calibration is not used) |
| Operating temperature |
5°C to 40°C (41°F to 104°F), 85%RH or less (No condensation) |
| Sensing method |
Super Hybrid Sensor (SHS) *SHS: Patent issued and pending |
| Display type |
Vacuum Fluorescent Display (VFD) |
| Display refresh rate |
5 times/second or 10 times/second |
| Counting mode |
Minimum unit mass |
0.001g |
0.001g |
| Number of samples |
10, 25, 50 or 100 pieces |
| Percent mode |
Minimum 100% reference mass |
0.100g |
1.00g |
| Minimum 100% display |
0.01%, 0.1%, 1% (Depends on reference mass stored) |
| Standard serial I/F |
RS-232C Interface with Windows Communication Tools (WinCT: included as CD-ROM) |
| Weighing pan |
128 x 128mm (5.04 x 5.04inch) |
165 x 165mm (6.50 x 6.50inch) |
| Calibration |
Motor-driven Internal Calibration (GX only) |
| External dimensions |
210(W) x 317(D) x 86(H)mm (8.27 x 12.48 x 3.39inch) |
| AC adapter |
Confirm that the adapter type is correct for the local voltage and power receptacle |
| Power consumption |
Approx. 11VA (supplied by AC adapter) |
| Net weight |
Approx. 4.6kg(GX)/3.8kg(GF) |
Approx. 5.1kg(GX)/4.3kg(GF) |  
| Specifications |
GF-2000* |
GF-3000* |
GF-4000 |
GF-6100 |
GF-6000* |
GF-8000 |
| Weighing capacity |
2100g |
3100g |
4100g |
6100g |
6100g |
8100g |
| Minimum weighing value |
0.01g |
0.1g |
| Repeatability (Standard Deviation) |
0.01g |
0.1g |
| Decimal ounce (oz) |
74.0755x0.0005 |
109.3495x0.0005 |
144.6230x0.0005 |
215.1710x0.0005 |
215.170x0.005 |
285.720x0.005 |
| Troy ounce (ozt) |
67.5165x0.0005 |
99.6675x0.0005 |
131.8180x0.0005 |
196.1195x0.0005 |
196.120x0.005 |
260.420x0.005 |
| Pennyweight (dwt) |
1350.33x0.01 |
1993.35x0.01 |
2636.36x0.01 |
3922.39x0.01 |
3922.4x0.1 |
5208.4x0.1 |
| Carat (ct) |
10500.00x0.05 |
15500.00x0.05 |
20500.00x0.05 |
30500.00x0.05 |
30500.0x0.5 |
40500.0x0.5 |
| Momme (mom) |
560.000x0.005 |
826.665x0.005 |
1093.335x0.005 |
1626.665x0.005 |
1626.65x0.05 |
2160.00x0.05 |
| Grain unit (GN) |
32408.0x0.2 |
47840.4x0.2 |
63272.6x0.2 |
94137.4x0.2 |
94138x2 |
125002x2 |
| Pound (lb) |
4.62970x0.00005 |
6.83435x0.00005 |
9.03895x0.00005 |
13.44820x0.00005 |
13.4480x0.0005 |
17.8575x0.0005 |
| Pound/Ounce (lb/oz) |
4Lb 10.08oz x0.01oz |
6Lb 13.35oz x0.01oz |
9Lb 0.62oz x0.01oz |
13Lb 7.17ozx0.01oz |
13Lb 7.17oz x0.01oz |
17Lb 13.72oz x0.01oz |
| Linearity |
0.02g |
0.03g |
0.1g |
| Stabilization time (typical at FAST) |
Approx. 1 second |
Approx. 1.5 second |
Approx. 1 second |
| Sensitivity drift (10C to 30C/50F-80F) |
2ppm/°C (When automatic self calibration is not used) |
±5ppm/°C (auto-self calibration OFF) |
| Operating temperature |
5°C to 40°C (41°F to 104°F), 85%RH or less (No condensation) |
| Sensing method |
Super Hybrid Sensor (SHS) *SHS: Patent issued and pending |
| Display type |
Vacuum Fluorescent Display (VFD) |
| Display refresh rate |
5 times/second or 10 times/second |
| Counting mode |
Minimum unit mass |
0.001g |
0.1g |
| Number of samples |
10, 25, 50 or 100 pieces |
| Percent mode |
Minimum 100% reference mass |
1.00g |
10.0g |
| Minimum 100% display |
0.01%, 0.1%, 1% (Depends on reference mass stored) |
| Standard serial I/F |
RS-232C Interface with Windows Communication Tools (WinCT: included as CD-ROM) |
| Weighing pan |
165 x 165mm (6.50 x 6.50inch) |
| Calibration |
Motor-driven Internal Calibration (GX only) |
| External dimensions |
210(W) x 317(D) x 86(H)mm (8.27 x 12.48 x 3.39inch) |
| AC adapter |
Confirm that the adapter type is correct for the local voltage and power receptacle |
| Power consumption |
Approx. 11VA (supplied by AC adapter) |
| Net weight |
Approx. 5.1kg(GX)/4.3kg(GF) | Notes: The internal mass is equal to (approximately) 500 grams. Standard breeze included for GX-200/400/600 and GF-200/300/400/600
*NTEP Class II and meets Pharmacopia Requirements CofC 03-005. 
Accessories: AD-1682 Rechargeable Battery Pack AD-8920 Universal Remote Display SW:128 Foot Switch TB:110 AC Adapter (120V) Standard with Unit GX-04 Comparator Output GX-06 Analog Output Factory Installed Only GX-10 Glass Breeze Break for GX-200/400/600 GX-11 Glass Breeze Break for GX-2000/4000/6100/6000/8000 GX-12 Animal Weighing Pan for GX-400/600/2000/4000/6100/6000/8000 GX-13 Density Determination Kit for GX-200/400/600 AX-073003691-S Protective Cover for GX-200/400/600 AX-073003692-G Protective Cover for GX-2000/4000/6100/6000/8000 CC:102E Carrying Case TB:123 AC Adapter (220V) AD-1682 Rechargeable Battery Pack AD-1682 Rechargeable Battery Pack
|