|
|
|
S Beam Stainless Steel Load Cell - 101BS
|
|
|
|
S Beam Stainless Steel Load Cell - 101BS
|
|
by Anyload
|
|
|
|
Available Options/Models:
|
|
|
|
|
|
|
Description
Buy 5 pcs get 1 free!
S type load cell.
FEATURES:
» High accuracy up to 5 000d for scales class III
» Stainless steel, welded seal construction,
protection to IP68
» Hostile or clean environment
» Tension & compression measurements, compatible with REM/REN & TEA tension hardware
» Hazardous area approved to Ex ib II CT4
» Available Options:
- Service temperature range up to 120? [248 ?]
- Available with metric and US threads
- 6-wire circuit
APPLICATIONS:
» Suspended hopper and tank
» Overhead crane scale
» Material test machine
» Washdown or corrosive application

Dimensions (in inches; 1inch = 25.4 mm)
FAQ's
What if we would like to purchase multiple load cells?
A: Please call in your order to order multiple pieces.
Will this load cell measure compression and tension?
A: Yes, this load cell will measure compression and tension.
|
|
Specifications
| Model # |
Capacity |
Material |
Interchangeable Models |
List Price |
Your Price |
| 101BS-500lb-3klb |
500lb;1K;2K;3Klb |
SS Weld Sealed |
SS, IP68, Sensortronics 60063, Rice Lake RL20001; Flintec UB6, Celtron STC HSS 620 |
$215.00 |
$140.00 |
| 101BS-5K |
5,000lb |
SS Weld Sealed |
SS, IP68, Sensortronics 60063, Rice Lake RL20001; Flintec UB6, Celtron STC HSS 620 |
$295.00 |
$170.00 |
| 101BS-10K |
10,000lb |
SS Weld Sealed |
SS, IP68, Sensortronics 60063, Rice Lake RL20001; Flintec UB6, Celtron STC HSS 620 |
$315.00 |
$185.00 |
| 101BS-15K |
15,000lb |
SS Weld Sealed |
SS, IP68, Sensortronics 60063, Rice Lake RL20001; Flintec UB6, Celtron STC HSS 620 |
$365.00 |
$255.00 |
| 101BS-20K |
20,000lb |
SS Weld Sealed |
SS, IP68, Sensortronics 60063, Rice Lake RL20001; Flintec UB6, Celtron STC HSS 620 |
$685.00 |
$370.00 |
2 Year Warranty
| Technical Data |
|
| |
| Type |
101BS |
|
Accuracy class according to OIML R60 or NTEP
Maximal numbers of load cell verification intervals (nLC)
|
C3 / NTEP III 5 000 Multiple Cell
3 000 / 5 000
|
|
Maximal capacity (Emax)
Minimum load cell verification interval (Vmin)
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin) *
Repeatability (drep) *
Hysteresis error (dhy) *
Creep (dDR)in 30 min.
Input resistance (RLC)?Red(+)-black(-)?
Output resistance (Ro) ?Green(+)-white(-)?
Reference excitation voltage (Uref)
Maximal excitation voltage
Insulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range
|
lb/kg
% of Cn
mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
O
O
V(DC/AC)
V(DC/AC)
GO
?[oF]
?[oF]
?[oF]
|
500;1,000;1,500;2,000;2,500;3,000;5,000;10,000;
15,000;20,000/300;500;1,000;2,000;5,000;10,000
0.02
2.0 +25%/ - 10%
±0.06
< ±0.0012
<±0.0040
<±0.023
<±0.030
<±0.030
< ±0.030
400 ±20
352±3
0.5…10
15
>2[50 VDC ]
-10…+40[15…+105]
-18…+65[0…+150]
-50…+85[-60…+185]
|
|
Safe load limit (EL)
Breaking load (Ed)
|
% of Cn
% of Cn
|
150
300
|
|
Protection class (IP) acc. to IEC529
|
|
IP68 |
|
Material
|
|
Stainless steel 17-4PH |
| Optionally |
|
Explosion proof version (Ex ib II CT4) |
|
Interchangeable Products
|
|
Flintec |
ULB |
| Rice Lake |
RL20001 |
| Celtron |
STC-HSS/620 |
| Sensortronics |
60063 |
|
|
| |
* The data for deviation of linearity, repeatability, hysteresis error and temperature effect on sensitivity are typical values. The sum of these data meets the requirements according to OIML R60 or NTEP 1:5 000 class III, Multiple Cell.
|
|
|
|
|
|
|
|
|